WHEATON
800.225.1437 (U.S. & Canada Only) | 856.825.1100 | 856.825.1368 (F) |
www.wheaton.com> 110
Liquid Handling
Cat. No.
Cat. No.
Inaccuracy (E%)
Imprecision (CV%)
Initial Package Pipette Alone
Volume
Division
Min. vol.
Mid. Vol.
Max. Vol.
Min. Vol.
Mid. Vol.
Max. Vol.
Tip Style
Micropipettes Acura
®
electro
926XS
W870902-A W870902
0.1 - 2µL
0.01µL
<± 2.5 %
1)
<± 1.2 % <± 0.9 % < 2.5 %
1)
< 1.5 % < 0.8 %
10µL
W870904-A W870904
0.5 - 10µL
0.05µL
<±1.2 %
2)
<± 0.8 % <± 0.6 % < 1.5 %
2)
< 0.7 % < 0.35 %
10µL
W870906-A W870906
0.5 - 10YµL*
0.05µL
<± 1.2 %
2)
<± 0.8 % <± 0.6 % < 1.7 %
2)
< 0.8 % < 0.4 %
200µL
W870908-A W870908
1 - 20µL
0.1µL
<± 1.2 %
2)
<± 0.6 % <± 0.5 % < 1.2 %
2)
< 0.4 % < 0.3 %
200µL
W870910-A W870910
2.5 - 50µL
0.25µL
<± 1.0 %
2)
<± 0.6 % <± 0.5 % < 0.7 %
2)
< 0.3 % < 0.25 %
200µL
W870912-A W870912
5 - 100µL
0.5µL
<± 1.0 %
2)
<± 0.6 % <± 0.5 % < 0.7 %
2)
< 0.3 % < 0.2 %
200µL
W870914-A W870914
10 - 200µL
1.0µL
<± 1.0 %
2)
<± 0.6 % <± 0.4 % < 0.6 %
2)
< 0.2 % < 0.15 %
200µL
W870916-A W870916
50 - 1000µL
5.0µL
<± 0.8 %
2)
<± 0.5 % <± 0.4 % < 0.4 %
2)
< 0.15 % < 0.1 %
1000µL
Macropipettes Acura
®
electro
936
W870918-A W870918
0.1 - 2mL
0.01mL
<± 1.5 %
2)
<± 1.0 % <± 0.5 % < 0.6 %
2)
< 0.3 % < 0.15 %
2mL
W870920-A W870920
0.25 - 5mL
0.05mL
<± 1.2 %
2)
<± 0.8 % <± 0.5 % < 0.6 %
2)
< 0.3 % < 0.15 %
5mL
W870922-A W870922
0.5 - 10mL
0.05mL
<± 1.0 %
2)
<± 0.7 % <± 0.5 % < 0.5 %
2)
< 0.2 % < 0.15 %
10mL
8-Channel Pipettes Acura
®
electro
956
W870924-A W870924
0.5 - 10µL
0.05µL
<± 3.5 %
2)
<± 1.5 % <± 1.0 % < 3.0 %
2)
< 0.9 % < 0.7 %
10µL
W870926-A W870926
2.5 - 50µL
0.25µL
<± 1.0 %
2)
<± 0.9 % <± 0.8 % < 1.0 %
2)
< 0.6 % < 0.4 %
200µL
W870928-A W870928
10 - 200µL
1.0µL
<± 0.9 %
2)
<± 0.7 % <± 0.6 % < 0.6 %
2)
< 0.4 % < 0.25 %
200µL
W870930-A W870930
20 - 350µL
5.0µL
<± 1.0 %
2)
<± 0.8 % <± 0.6 % < 0.6 %
2)
< 0.4 % < 0.25 %
350µL
12-Channel Pipettes Acura
®
electro
956
W870932-A W870932
0.5 - 10µL
0.05µL
<± 3.5 %
2)
<± 1.5 % <± 1.0 % < 3.0 %
2)
< 0.9 % < 0.7 %
10µL
W870934-A W870934
2.5 - 50µL
0.25µL
<± 1.0 %
2)
<± 0.9 % <± 0.8 % < 1.0 %
2)
< 0.6 % < 0.4 %
200µL
W870936-A W870936
10 - 200µL
1.0µL
<± 0.9 %
2)
<± 0.7 % <± 0.6 % < 0.6 %
2)
< 0.4 % < 0.25 %
200µL
W870938-A W870938
20 - 350µL
5.0µL
<± 1.0 %
2)
<± 0.8 % <± 0.6 % < 0.6 %
2)
< 0.4 % < 0.25 %
350µL
Performance values obtained in Forward mode with double-distilled water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.
Performance measured at:
1)
0.5 µL,
2)
10% of nominal volume
* This pipette must be used with a 200µL pipette tip
Ordering Information
Initial package includes pipette, charging stand and accessories. Additional pipettes (alone) supplied with individual QC certificate, pipette tips samples and operating instructions.
Micropipettes
■
Reduced shaft length and conical end improve driveability
■
Easy access to microtubes and microplates
■
Optional longer volumetric modules
■
Simple conversion by user at any time
■
Unsurpassed metrological performance and stability
Macropipettes
■
Interchangeable nozzle protection filter
■
Adapters for Pasteur pipette and straw tips
■
Outstanding accuracy and precision
Multichannel
■
Large selection of 8 and 12-channel models
■
Lightweight and perfect hand fitting
■
Sequential tip ejection
■
Also fits any single channel volumetric module
Acura
®
electro
926 XS / 936 / 956 Electrontic Pipettes